Conduct Test (with knob) – Step 4 in the DU200 DucTester QuickGuide
Connect the flex-duct flange to the duct inlet.
Ensure all supply and return registers are properly sealed with grill mask.
On the DMā2 gauge, set time averaging to ~10āÆs.
Set the range configuration (Mid or Low) to match duct flow.
Ensure auto-zero is enabled, and the display shows the desired pressure units (e.g., CFM@25āÆPa).
Maintain the set pressure until readings stabilize (typically 20ā60āÆs depending on conditions).
Record the airflow reading (e.g., CFM@25āÆPa) from Channel B.
If the target pressure isnāt reached at full speed:
Confirm all registers are sealed.
Try a less restrictive range (Open).
If Channel B shows āTOO LOWā:
The flow is insufficient for the current rangeāinstall a more restrictive plate and adjust again ([turn0search3]).
If fan speed isnāt responding:
Check power connection.
Ensure the speed cable is fully disconnected or reconnected according to test setup.
Manual mode offers a reliable backup method when automatic control fails or is unavailable.
Proper pressure control by knob ensures meaningful, repeatable data even without software.
Flexibilityāthis mode supports nearly all rapid residential duct leakage testing protocols.