Connect to ducts – Step 2 in the DU200 DucTester QuickGuide
What This Step Covers Connecting flex duct to return or supply registersUse the supplied flex duct and adjustable collar to form an airtight seal over the register opening. Securing the…
What This Step Covers Connecting flex duct to return or supply registersUse the supplied flex duct and adjustable collar to form an airtight seal over the register opening. Securing the…
Seal & Secure the Duct System Seal all supply and return registersāincluding exterior inletsāusing grill mask tape to prevent air bypass. Keep interior doors open to allow duct pressure to…
Problem #1: Flow Reads ā–ā at Test Pressure What this Means: You’ve reached the target pressure (e.g., 25āÆPa), but the gauge shows no flow data. Why it Happens: Fan pressure…
Unpack and Power Up Open the DucTester kit case and remove all components: fan, gauge, umbilical (pressure tubes + speed control cable), flex duct with flange, range rings, grill masking…
https://youtu.be/4NFEIVd7rcY
What You’ll Need DMā2 digital gauge (with full battery or USB power) DucTester fan (ModelāÆ200) Umbilical cable (pressure tubes + speed-control cable) Flex duct and register flange Connecting to the…
Method Overview: One-Gauge Pressurization Unlike dual-gauge methods, this technique requires the tester to manually alternately measure house pressure and duct pressure with a single gauge: Set Up Equipment Connect the…
How to Perform the Test Prepare for Depressurization Connect the flex-duct flange to the duct inlet. Ensure all supply and return registers are properly sealed with grill mask. Configure the…