- Overview Features
- Included Items
- Tech Specs
- Manuals & Guides
A Hard Panel Blower Door System for Large-Scale Applications
Retrotecās Model 6120 Hard Panel System offers high performance, professional appearance, and rapid setup, making it a top choice for leading building science companies. Designed for efficiency in large commercial and multi-story buildings, this system reduces the number of high-power fans required per floor, streamlining airtightness testing like never before.
Why Choose the Model 6120?
The Model 6120 combines the high power of the Model 6100 with Retrotecās exclusive hard panel system, providing a clean, professional setup with incredibly fast installation. The hard panel design eliminates the need for cloth frames, reducing setup time while improving stability and durability.
Multi-story buildings benefit from the system’s high output, often requiring only one or two fans per floor to achieve precise test pressures. The Model 6120 ensures reliable and repeatable test results for even the most demanding projects. This choice is a go-to solution for professionals who require speed, power, and professional presentation in their airtightness testing.
Who Uses the Model 6120?
Trusted by energy auditors, HVAC contractors, building contractors, remodelers, and home inspectors, this system is ideal for large commercial and multi-unit residential airtightness testing.
1 x 6000 Series Fan Set
- 6000 Series Calibrated Fan
(120V/60Hz, 240V/50Hz, or 110V/50Hz) - Range Ring A
- B8 Plate
- 8 x Blank Range Plugs
- Blower Door Tubing Kit
- Tubing Umbilical
- Fan Cover
- Power Cord
- System Calibration Verification Report
1 x Hard Panel SetĀ for 1000/5000/6000 Series Fan
1 x DM32X Gauge Package
- DM32X Gauge
- Gauge Case
- USB-C Charging Cable
- Cat5 Cable
- ISO17025 calibration of DM32X
- Gauge Calibration Verification Report
1 x Fan Case
1 x System Accessories Case
| Model 6000 Fan | ||||
| Flow Into: | CFM | Litres/sec | M3/h | |
| Max Flow, per fan (60 Hz)
Reduces values by 15% for 50Hz fan |
Free Air | 8,100 | 3,823 | 13,762 |
| 50 Pa | 7,700 | 3,634 | 13,082 | |
| 75 Pa | 7,400 | 3,492 | 12,573 | |
| Minimum Flow: | Ā | |||
| on Included Range B1 | 50 Pa | 95 | 49 | 161 |
| on Optional Range 74 | 50 Pa | 37 | 17 | 63 |
| on Optional Range 47 | 50 Pa | 21 | 10 | 35 |
| on Optional Range 29 | 50 Pa | 9 | 4 | 15 |
| Dimensions: | 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height | |||
| Weight: | 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed | |||
| Flow Accuracy: | +/-5% | |||
| Power: | 120V@60hz/22.0A or 240V@50hz/10.9A or 110V@50Hz/22.0A | |||
| Recommended Fan Calibration Interval: | 5 years | |||
| Digital Gauge Model: | DM32X (Click Here) | |||
Manuals
- Manual- Blower Door Operation for Model 300 5000 6000 7000
- Manual- Residential Pressure & Air Leakage Testing
- Manual- Blower Door Multiple Fan Operation for Model 300 5000 6000 7000
QuickGuides
- QuickGuide- Blower Door with DM32X for Model 300 5000 6000 7000
- QuickGuide- Blower Door with DM32 for Model 5000 6000
- QuickGuide- Cloth Door Panel
- QuickGuide- Blower Door Range Configuration for 5000 6000
- QuickGuide- Modular Door Panel
MoreĀ
- Overview Features
- Included Items
- Tech Specs
- Manuals & Guides
A Hard Panel Blower Door System for Large-Scale Applications
Retrotecās Model 6120 Hard Panel System offers high performance, professional appearance, and rapid setup, making it a top choice for leading building science companies. Designed for efficiency in large commercial and multi-story buildings, this system reduces the number of high-power fans required per floor, streamlining airtightness testing like never before.
Why Choose the Model 6120?
The Model 6120 combines the high power of the Model 6100 with Retrotecās exclusive hard panel system, providing a clean, professional setup with incredibly fast installation. The hard panel design eliminates the need for cloth frames, reducing setup time while improving stability and durability.
Multi-story buildings benefit from the system’s high output, often requiring only one or two fans per floor to achieve precise test pressures. The Model 6120 ensures reliable and repeatable test results for even the most demanding projects. This choice is a go-to solution for professionals who require speed, power, and professional presentation in their airtightness testing.
Who Uses the Model 6120?
Trusted by energy auditors, HVAC contractors, building contractors, remodelers, and home inspectors, this system is ideal for large commercial and multi-unit residential airtightness testing.
1 x 6000 Series Fan Set
- 6000 Series Calibrated Fan
(120V/60Hz, 240V/50Hz, or 110V/50Hz) - Range Ring A
- B8 Plate
- 8 x Blank Range Plugs
- Blower Door Tubing Kit
- Tubing Umbilical
- Fan Cover
- Power Cord
- System Calibration Verification Report
1 x Hard Panel SetĀ for 1000/5000/6000 Series Fan
1 x DM32X Gauge Package
- DM32X Gauge
- Gauge Case
- USB-C Charging Cable
- Cat5 Cable
- ISO17025 calibration of DM32X
- Gauge Calibration Verification Report
1 x Fan Case
1 x System Accessories Case
| Model 6000 Fan | ||||
| Flow Into: | CFM | Litres/sec | M3/h | |
| Max Flow, per fan (60 Hz)
Reduces values by 15% for 50Hz fan |
Free Air | 8,100 | 3,823 | 13,762 |
| 50 Pa | 7,700 | 3,634 | 13,082 | |
| 75 Pa | 7,400 | 3,492 | 12,573 | |
| Minimum Flow: | Ā | |||
| on Included Range B1 | 50 Pa | 95 | 49 | 161 |
| on Optional Range 74 | 50 Pa | 37 | 17 | 63 |
| on Optional Range 47 | 50 Pa | 21 | 10 | 35 |
| on Optional Range 29 | 50 Pa | 9 | 4 | 15 |
| Dimensions: | 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height | |||
| Weight: | 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed | |||
| Flow Accuracy: | +/-5% | |||
| Power: | 120V@60hz/22.0A or 240V@50hz/10.9A or 110V@50Hz/22.0A | |||
| Recommended Fan Calibration Interval: | 5 years | |||
| Digital Gauge Model: | DM32X (Click Here) | |||
Manuals
- Manual- Blower Door Operation for Model 300 5000 6000 7000
- Manual- Residential Pressure & Air Leakage Testing
- Manual- Blower Door Multiple Fan Operation for Model 300 5000 6000 7000
QuickGuides
- QuickGuide- Blower Door with DM32X for Model 300 5000 6000 7000
- QuickGuide- Blower Door with DM32 for Model 5000 6000
- QuickGuide- Cloth Door Panel
- QuickGuide- Blower Door Range Configuration for 5000 6000
- QuickGuide- Modular Door Panel
MoreĀ
Related Products
Model 6210
$13,275.00 – $14,280.00Price range: $13,275.00 through $14,280.00Model 5120
$6,650.00 – $6,980.00Price range: $6,650.00 through $6,980.00Model 6100
$6,875.00 – $7,610.00Price range: $6,875.00 through $7,610.00Model 5100
$4,825.00 – $5,400.00Price range: $4,825.00 through $5,400.00Request a Quote
Talk with a Sales Rep
Resellers, Testers, Trainers