Product code: 6310

Model 6310

Price range: $18,800.00 through $20,265.00

A Triple Hi-Power Blower Door System for Large-Scale Testing

Retrotec’s Model 6300 Blower Door System is the go-to solution for airtightness testing in warehouses, large stores, and office buildings. Equipped with three Model 6000 Calibrated Fans within a large cloth panel door frame system, this high-performance setup is designed to move massive volumes of air, making it the go-to choice for commercial, multi-family, and high-rise building testing.

Unlike traditional blower door systems with ¾ hp fans, the Model 6300 features powerful 1 hp fans, delivering superior performance with enhanced speed stability. Its hi-power fans provide a much wider flow range, allowing multi-point tests to be completed automatically without changing fan ranges—saving time while improving accuracy.

With a single Ethernet cable connecting the test area to a laptop, the need for extended umbilicals is eliminated, streamlining the testing process.

The Model 6300 is built for professionals who require high performance levels, offering power, stability, and ease of use for demanding applications.

Who Uses the Model 6300?

Energy auditors, HVAC contractors, building contractors, remodelers, and home inspectors rely on the Model 6300 for large-scale airtightness testing where power, accuracy, and efficiency are essential.

 

3 x 6000 Series Fan Set

  • 6000 Series Calibrated Fan
    (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • High Power Drive
    (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • Range Ring A
  • B8 Plate
  • 8 x Blank Range Plugs
  • Blower Door Tubing Kit
  • Tubing Umbilical
  • Fan Cover
  • Power Cord
  • System Calibration Verification Report

1 x Triple Fan SmartClothā„¢ Door Panel & Frame

  • Triple Fan Large SmartClothā„¢ Wind Dampening Cloth Door
  • Single Fan Large SmartClothā„¢ Wind Dampening Cloth Door
  • Large Aluminum Frame, Etched with Sizing Markings
  • Traveling Case

3 x DM32X Gauge Package

  • DM32X Gauge
  • Gauge Case
  • USB-C Charging Cable
  • Cat5 Cable
  • ISO17025 calibration of DM32X
  • Gauge Calibration Verification Report

3 x Fan Case

3 x System Accessories Case

FanTestic Pro 6 Reporting Software

Model 6000 Fan
Flow Into: CFM Litres/sec M3/h
Max Flow, per fan (60 Hz)

Reduces values by 15% for 50Hz fan

Free Air 8,100 3,823 13,762
50 Pa 7,700 3,634 13,082
75 Pa 7,400 3,492 12,573
Minimum Flow: Ā 
on Included Range B1 50 Pa 95 49 161
on Optional Range 74 50 Pa 37 17 63
on Optional Range 47 50 Pa 21 10 35
on Optional Range 29 50 Pa 9 4 15
Dimensions: 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height
Weight: 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed
Flow Accuracy: +/-5%
Power: 120V@60hz/22.0A or 240V@50hz/10.9A or 110V@50Hz/22.0A
Recommended Fan Calibration Interval: 5 years
Digital Gauge Model: DM32X (Click Here)

A Triple Hi-Power Blower Door System for Large-Scale Testing

Retrotec’s Model 6300 Blower Door System is the go-to solution for airtightness testing in warehouses, large stores, and office buildings. Equipped with three Model 6000 Calibrated Fans within a large cloth panel door frame system, this high-performance setup is designed to move massive volumes of air, making it the go-to choice for commercial, multi-family, and high-rise building testing.

Unlike traditional blower door systems with ¾ hp fans, the Model 6300 features powerful 1 hp fans, delivering superior performance with enhanced speed stability. Its hi-power fans provide a much wider flow range, allowing multi-point tests to be completed automatically without changing fan ranges—saving time while improving accuracy.

With a single Ethernet cable connecting the test area to a laptop, the need for extended umbilicals is eliminated, streamlining the testing process.

The Model 6300 is built for professionals who require high performance levels, offering power, stability, and ease of use for demanding applications.

Who Uses the Model 6300?

Energy auditors, HVAC contractors, building contractors, remodelers, and home inspectors rely on the Model 6300 for large-scale airtightness testing where power, accuracy, and efficiency are essential.

 

3 x 6000 Series Fan Set

  • 6000 Series Calibrated Fan
    (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • High Power Drive
    (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • Range Ring A
  • B8 Plate
  • 8 x Blank Range Plugs
  • Blower Door Tubing Kit
  • Tubing Umbilical
  • Fan Cover
  • Power Cord
  • System Calibration Verification Report

1 x Triple Fan SmartClothā„¢ Door Panel & Frame

  • Triple Fan Large SmartClothā„¢ Wind Dampening Cloth Door
  • Single Fan Large SmartClothā„¢ Wind Dampening Cloth Door
  • Large Aluminum Frame, Etched with Sizing Markings
  • Traveling Case

3 x DM32X Gauge Package

  • DM32X Gauge
  • Gauge Case
  • USB-C Charging Cable
  • Cat5 Cable
  • ISO17025 calibration of DM32X
  • Gauge Calibration Verification Report

3 x Fan Case

3 x System Accessories Case

FanTestic Pro 6 Reporting Software

Model 6000 Fan
Flow Into: CFM Litres/sec M3/h
Max Flow, per fan (60 Hz)

Reduces values by 15% for 50Hz fan

Free Air 8,100 3,823 13,762
50 Pa 7,700 3,634 13,082
75 Pa 7,400 3,492 12,573
Minimum Flow: Ā 
on Included Range B1 50 Pa 95 49 161
on Optional Range 74 50 Pa 37 17 63
on Optional Range 47 50 Pa 21 10 35
on Optional Range 29 50 Pa 9 4 15
Dimensions: 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height
Weight: 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed
Flow Accuracy: +/-5%
Power: 120V@60hz/22.0A or 240V@50hz/10.9A or 110V@50Hz/22.0A
Recommended Fan Calibration Interval: 5 years
Digital Gauge Model: DM32X (Click Here)
5000 Fan Max Flows
5,700 CFM50 Ā· 2,690 l/s Ā· 9,684 M3/h
6000 Fan Max Flows
7,700 CFM50 Ā· 3,634 l/s Ā· 13,082 M3/h
7000 Fan Max Flows (Battery)
8,413 CFM CFM50 Ā· 14,302 l/s Ā· 3,970 M3/h

Request a Quote

Talk with a Sales Rep

Resellers, Testers, Trainers