Connect a tube between the Input A (blue) and Input B (green) ports.
After readings stabilize, both channels should match within ±2%.
Disconnect blue/green tube and connect Ref A (red) to Ref B (yellow) ports.
Again, ensure readings are within ±2%.
For extra assurance, connect each matching port between two gauges (e.g., blue-to-blue).
Readings should agree within ±2%, confirming accuracy.
If readings donāt match:
Replace or straighten tubing; test ports individually to isolate the issue.
Raise Time Averaging to 4āÆs if readings are noisy.
Clear baseline before retesting.
Persisting discrepancies? Try another gauge for a final check before recalibration.