Product code: 5100F

Model 5100F [Enclosure Integrity]

Price range: $6,500.00 through $7,190.00

The Complete Entry-Level Enclosure Integrity Testing System

Retrotec’s Model 5100F is the ideal solution for entry-level enclosure integrity testing, providing everything you need to accurately test hold times and venting requirements in a wide range of enclosures.

This system allows for hold time testing in flooded volumes up to 35,000 cubic feet (1000 m³) for Inert agents and up to 70,000 cubic feet (2000 m³) for halocarbon chemical agents. Additionally, vent testing can be conducted for volumes up to 9,000 cubic feet (250 m³) for Inert agents, with the capability to measure individual vents up to 6 square feet (0.6 m²).

The Model 5100F includes the newly released, industry-changing DM32X gauge, ensuring precision and reliability in every test.

Why Choose Retrotec for Enclosure Integrity Testing?

Retrotec pioneered Enclosure Integrity testing in 1984, introducing the concept to NFPA and writing the first Enclosure Integrity standard in 1986. With decades of research and development, Retrotec remains the global leader in enclosure testing. Every major clean agent system manufacturer worldwide relies on Retrotec’s expertise for both hold time and peak pressure predictions.

Request detailed literature on Retrotec’s full range of systems to determine the ideal solution for your specific enclosure size and testing needs. For applications involving pressure relief vent testing, additional power may be required to meet the necessary conditions.

1 x 5000 Series Fan Set

  • 5000 Series Calibrated Fan
    (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • Range Ring A
  • B8 Plate
  • 8 x Blank Range Plugs
  • Blower Door Tubing Kit
  • Tubing Umbilical
  • Fan Cover
  • Power Cord
  • System Calibration Verification Report

1 x SmartCloth™ Door Panel & Frame

  • SmartCloth™ Wind Dampening Cloth Door
  • Aluminum Frame, Etched with Sizing Markings
  • Traveling Case

1 x DM32X Gauge Package

  • DM32X Gauge
  • Gauge Case
  • USB-C Charging Cable
  • Cat5 Cable
  • ISO17025 calibration of DM32X
  • Gauge Calibration Verification Report

1 x System Accessories Case

1 x Fan Case

4 x Roll of Grill Masks

Model 5000 Fan
Flow Into: CFM Litres/sec M3/h
Max Flow, per fan (60 Hz)

Reduces values by 15% for 50Hz fan

Free Air 6,400 3,020 10,874
50 Pa 5,700 2,690 9,684
75 Pa 5,400 2,549 9,175
Minimum Flow:  
on Included Range B1 50 Pa 111 52 188
on Optional Range 74 50 Pa 37 17 63
on Optional Range 47 50 Pa 21 10 35
on Optional Range 29 50 Pa 9 4 15
Dimensions: 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height
Weight: 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed
Flow Accuracy: +/-5%
Power: 120V@60hz/11A or 240V@50hz/4.9A or 110V@50Hz/ 8.9A
Recommended Fan Calibration Interval: 5 years
Digital Gauge Model: DM32X (Click Here)

The Complete Entry-Level Enclosure Integrity Testing System

Retrotec’s Model 5100F is the ideal solution for entry-level enclosure integrity testing, providing everything you need to accurately test hold times and venting requirements in a wide range of enclosures.

This system allows for hold time testing in flooded volumes up to 35,000 cubic feet (1000 m³) for Inert agents and up to 70,000 cubic feet (2000 m³) for halocarbon chemical agents. Additionally, vent testing can be conducted for volumes up to 9,000 cubic feet (250 m³) for Inert agents, with the capability to measure individual vents up to 6 square feet (0.6 m²).

The Model 5100F includes the newly released, industry-changing DM32X gauge, ensuring precision and reliability in every test.

Why Choose Retrotec for Enclosure Integrity Testing?

Retrotec pioneered Enclosure Integrity testing in 1984, introducing the concept to NFPA and writing the first Enclosure Integrity standard in 1986. With decades of research and development, Retrotec remains the global leader in enclosure testing. Every major clean agent system manufacturer worldwide relies on Retrotec’s expertise for both hold time and peak pressure predictions.

Request detailed literature on Retrotec’s full range of systems to determine the ideal solution for your specific enclosure size and testing needs. For applications involving pressure relief vent testing, additional power may be required to meet the necessary conditions.

1 x 5000 Series Fan Set

  • 5000 Series Calibrated Fan
    (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • Range Ring A
  • B8 Plate
  • 8 x Blank Range Plugs
  • Blower Door Tubing Kit
  • Tubing Umbilical
  • Fan Cover
  • Power Cord
  • System Calibration Verification Report

1 x SmartCloth™ Door Panel & Frame

  • SmartCloth™ Wind Dampening Cloth Door
  • Aluminum Frame, Etched with Sizing Markings
  • Traveling Case

1 x DM32X Gauge Package

  • DM32X Gauge
  • Gauge Case
  • USB-C Charging Cable
  • Cat5 Cable
  • ISO17025 calibration of DM32X
  • Gauge Calibration Verification Report

1 x System Accessories Case

1 x Fan Case

4 x Roll of Grill Masks

Model 5000 Fan
Flow Into: CFM Litres/sec M3/h
Max Flow, per fan (60 Hz)

Reduces values by 15% for 50Hz fan

Free Air 6,400 3,020 10,874
50 Pa 5,700 2,690 9,684
75 Pa 5,400 2,549 9,175
Minimum Flow:  
on Included Range B1 50 Pa 111 52 188
on Optional Range 74 50 Pa 37 17 63
on Optional Range 47 50 Pa 21 10 35
on Optional Range 29 50 Pa 9 4 15
Dimensions: 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height
Weight: 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed
Flow Accuracy: +/-5%
Power: 120V@60hz/11A or 240V@50hz/4.9A or 110V@50Hz/ 8.9A
Recommended Fan Calibration Interval: 5 years
Digital Gauge Model: DM32X (Click Here)
5000 Fan Max Flows
5,700 CFM50 · 2,690 l/s · 9,684 M3/h
6000 Fan Max Flows
7,700 CFM50 · 3,634 l/s · 13,082 M3/h
7000 Fan Max Flows (Battery)
8,413 CFM CFM50 · 14,302 l/s · 3,970 M3/h

Request a Quote

Talk with a Sales Rep

Resellers, Testers, Trainers

Retrotec Blower Door Systems