| DM32 Firmware | 2.5.51B1 /Ā 2.6.51B1 | Ā 2021-08-25 | Ā Current General Release for 10A/20 Gauges only ā 2.6 firmware version is for DM32 10A/20A gauges with the new screen controller - Added Remote Logging feature
- WifiĀ connectivity improved
- Support for 500 fan added
- Support forĀ RetrotecĀ Flow Box added
|
| DM32 Firmware | 2.5.35.B1Ā | 2018-09-18 | Current General Release for 10A and 20A gauges. Ā Bug Fix:Ā If Acquiring Baseline was active, and the user pressed the power button, the user was returned to the Gauge Screen, but Acquiring Baseline was still active.Ā |
| DM32 Firmware | 2.4.71B1 | 2015-12-01 | - When a pressure measurement exceeds the maximum pressure limit of the sensor, “+ +” flashes for that channel’s pressure/result
- The maximum allowable Set Pressure value for the gauge depends on the gauge’s pressure sensor.
E.g. the Set Pressure limit for “20A” gauges is 4983 Pa (~20 in WC) - If the Set Pressure value entered exceeds the Set Pressure limit, a warning message displays what the maximum allowable Set Pressure value is
- The n-value of 450 Device is changed to 0.65 for more realistic commercial duct flow extrapolation
- A designation appended to the firmware version (“B1” in this version) is shown on the splash screen and home screen; to indicate whichĀ RoundĀ of Published Flow Equation Parameters are used by the installed firmware version for its flow calculations
- Graphics changed for Range 102 to better distinguish Range 102 from Range Plugs; for 300, 340, 350 Devices
- Optimized Flow Equation Parameters of 450, 5000, 6000 Devices for improved flow accuracy
- New Opcode added, “WFAr”, retrieves: Serial Number, channel A pressure, channel B pressure, Fan Speed, Fan Index, Range Index, Flow
- Bug fix: Fan Speed for 400 Device stuck at 10% when Set Pressure value is greater than 1245 Pa
- Bug fix: 1000.0 Pa pressure measurement was incorrectly truncated to display as “000.0” Pa
- Bug fix: Flow calculations for 4000 Device involving channel A pressure needs to be computed as absolute value
|
| DM32 Firmware | 2.3.62 | 2015-06-22 | - EEpromĀ driver modified to support ISSIĀ EEpromĀ chip, which is replacing the SST25V.Ā
- Bug Fixes:Ā ISSIĀ EEpromĀ Write Routine had two very bad bugs, one of which was killing the SPI Driver.Ā
- Bug Fix:Ā Ā Factory Parameters were never sticking because the Factory Signature Word was never being written to nonvolatile memory.Ā
- SST25V ācompatible: Bug Fix: When PID Control was active, the PID algorithm was being temporarily degraded by a user entry of either a new AREA or VOLUME value.Ā
- New Flow control algorithm added for the Model 300 Fan.Ā
- Autosensing ofĀ EEpromĀ type causes dynamic switching betweenĀ EEpromĀ firmware drivers:Ā ISSI or SST25V.Ā
- Support added for three new fans:Ā 4000, 5000, and 6000.Ā
- UI improvements and bug fixes for fans 4000, 5000, andĀ 6000Ā
- Beeper driver has been restored to the pre- v2.2.56 version.Ā
- Fan 450 Bug Fix:Ā Fan 450 PID Ki setting was incorrectly documented to be zero.Ā
- Restored the Ki setting to 0.002.Ā
- Changes to Fan Coefficients Tables.Ā
- Fan 4000Ā underflow checking has been reversed.Ā
- Screen indices have been corrected.Ā
- 450 fan images were not being used.Ā
- Bug Fix:Ā 4000 Fan CFM results are now properly displayed in conformance with the defined range checking rules.Ā
- Bug Fix:Ā on the CLI interface, Fan 450 indices were off by one unit.Ā
- PID Change:Ā For the 450 Fan,Ā pIĀ = 0x00.Ā
- Bug #1586 fixed: 450 range settings were starting out wrong when a Set Device #450 CLI command was received.Ā
|
| DM32 Firmware | 2.2.49 | 2014-11-18 | - Bug Fix ā On the Splash Screen, added a Space Character between āSerial Numberā and the actual serial number.Ā
- Bug Fix:Ā At zeroĀ pascalsĀ Channel B pressure, flow (units of CFM) are calculated, and this should not happen since there would be no flow so it doesn’t make sense.Ā
- Sensor Type is now displayed on the Main Gauge Screen.Ā
- Bug Fix:Ā TRUE FLOW Range #14 and Range #20 āKā values had been accidently crisscrossed.Ā
- Bug Fix:Ā MN Exhaust Fan E3 K value was incorrectly set to 10.7.Ā It has been corrected to 10.07.Ā
- Pressure calculation limits for the 4ā sensor have been increased to +/-1245 Pa.Ā
- Bug Fix:Ā For the French Language, the Group Separator must be ā ā, not ā,ā.Ā (SPACE, not COMMA).Ā
- Bug Fix: Sending range = 1: device shows “TrueFlowĀ 20”. Sending range = 2: device shows “TrueFlowĀ Open” withĀ HoleFlowĀ iconĀ
- Bug Fix:Ā The max AREA or VOLUME value allowed to be entered via anĀ OPcodesĀ commands has been increased from 65,000 to 999,999.Ā
- Bug Fix:Ā Changes to the Hole Flow Area via opcode command were not being saved to nonvolatile memory.Ā
- RetrotecĀ device 360 has been renamed to Device ā450ā.Ā
|
| DM32 Firmware | 2.1.42 | 2014-09-15 | - New Set/Get Multiplier Opcodes have been added SET A:Ā WFAj, GET A:Ā WFAk, SET B:Ā WFAl, SET B:Ā WFAmĀ
- Bug Fix:Ā If the Hole Flow Area is updated by the opcode āWF]ā, then active screen is updated if that screen was displaying the Hole Flow area.Ā
- Feature Change:Ā Ā When opcode Set Pressure is executed (āWFeā), then if Set Pressure was not previously active, then
Ā Ā Ā 1) Set the initial fan speed for the PID to be the larger of the currently active fan speed or 10%, Ā Ā Ā 2) Set the target pressure to the incoming parameter, and Ā Ā Ā 3) Activate the Set Pressure PID.Ā Ā Ā Ā Else, if Set Pressure was already previously active, then Ā Ā Ā 1) Set the target pressure to the incoming parameters, and Ā Ā Ā 2) Continue the Set Pressure PID without any other changes.Ā - n-value display has been removed from the Settings Menu.
|
| DM32 Firmware | 2.1.34 | 2014-07-08 | - Increased Fan Speed Jog resolution to +/- 1%.Ā Ā Ā
- PID control settings for all Fan Devices have been improved.Ā Ā
- New Flow/Area units added: m3/(s*m2).Ā Ā Ā
- Five new Fan Devices added:Ā 300, 340, 350, 360, and 240.Ā Ā
- Flow Results – CFM results that are negative are now flipped to positive.Ā Ā Ā
- Metric suffixes have been revised.Ā Ā Ā
- Non Pressure outputs are rounded to 4 significant digits rather than 3.5.Ā Ā Ā
- Bug fix: In the Pressure B Display, sometimes the leading “0” was disappearing.Ā
|
| DM32 Firmware | 2.1.26 | 2013-12-16 | - Bug 1461 āre-fixedā:Ā Ā Ā Ā Ā AutozeroingĀ samples were leeching into the averaging filter.Ā
|
| DM32 Firmware | 2.1.15 | 2013-09-13 | - Bug #1417 has been fixed.Ā Ā Ā There will be no more inexplicableĀ wifiĀ dropouts while running in INFRASTRUCTURE Mode.Ā Ā
|